400kw AC Dummy Generator/Genset Resistive Load Bank for Generator Testing

Product Details
Customization: Available
After-sales Service: Technical Support,Training,Free Service
Material: Steel
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Registered Capital
2000000 RMB
Plant Area
101~500 square meters
  • 400kw AC Dummy Generator/Genset Resistive Load Bank for Generator Testing
  • 400kw AC Dummy Generator/Genset Resistive Load Bank for Generator Testing
  • 400kw AC Dummy Generator/Genset Resistive Load Bank for Generator Testing
  • 400kw AC Dummy Generator/Genset Resistive Load Bank for Generator Testing
  • 400kw AC Dummy Generator/Genset Resistive Load Bank for Generator Testing
  • 400kw AC Dummy Generator/Genset Resistive Load Bank for Generator Testing
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Detail Pictures
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
RKLB400KW
Type
Resistive Load Bank
Structure
Vertical
Warranty
1 Year
Protection Level
IP54
Voltage
380V/220VAC,3p4w
Rated Load
400kw
Application
Load Testing
Customized
Customized
Surface Treatment
Powder Coating
Name
400kw Resistive Load Bank
Control Mode
Local Panel Manual Control
Resolution
1kw
Design
Outdoor
Cooling
Forced Air Cooling
Color
Ral7035
Transport Package
Wooden Case + Pallet
Specification
1550*1450*1380mm
Origin
China
HS Code
9030899090
Production Capacity
5 Sets/Month

Product Description

400kW Resistive Load Bank|Dual Input Voltage|ISO9001/CE Certified
400kW resistive load bank with dual input voltage(380V/220VAC) and load banks will be placed on the truck to facilitate serving different local customers. So, we designed the load bank as following shows and kindly note that your inquiry/message will be replied soon(Less than 10 minutes).
Product Description
Technical Features
1) 400kW high power capacity, meets high-load testing requirements for generators, UPS, and energy storage systems; 
2) IP54 protection rating, weatherproof design for harsh environments, forced air cooling + high-temperature resistant alloy resistors ensure continuous full-load operation without derating; 
3) Precise adjustment with 1kW minimum step resolution for more reliable test data, manual knob + LCD panel provides intuitive operation and zero-delay response. 
4) Star-delta conversion design to ensure 400kW power for both 380V and 220V input voltage.
Application
400kw AC Dummy Generator/Genset Resistive Load Bank for Generator Testing
1) Generator set testing: validates steady-state and transient performance of diesel/gas generators
2) UPS power supply inspection: evaluates load capacity and transfer characteristics of uninterruptible power supplies
3) New energy system assessment: tests output stability of PV inverters and energy storage systems
4) Marine power verification: meets shore-based commissioning requirements for shipboard power systems
5) Data center acceptance: examines reliability of backup power systems
Technical Features
1) Pure resistive load simulates real-world power consumption
2) Precise power factor setting (typically 1.0)
3) Supports step-loading for dynamic response testing
4) More controllable and maintainable than inductive/capacitive loads)
Specification
400kW Resistive Load Bank Main Specification(Customized available)
Rated power
400kW(resistive only)
Rated voltage
380V/220VAC,3P4W,connected with tin plated voltage,star-delta conversion
Operate voltage
380VAC,3P4W,connected with water proof quick plug
Power factor
1.0
Load accuracy
±3%
Control mode
Local panel manual control(remote automatic control can be supplied)
Cooling
Forced air cooling,horizontal air discharge,dB≤80,1m
Resistor
Ni-Cr alloy resistor
Protection
Over voltage/current,short circuit,high temperature alam,low air volume alarm,emergency stop
Enclosure
Cold rolled steel with powder coated,customized color
Size
1550*1450*1380mm
Weight
650kgs
Detail Pictures
400kw AC Dummy Generator/Genset Resistive Load Bank for Generator Testing
400kw AC Dummy Generator/Genset Resistive Load Bank for Generator Testing
400kw AC Dummy Generator/Genset Resistive Load Bank for Generator Testing
400kw AC Dummy Generator/Genset Resistive Load Bank for Generator Testing
Company Profile
400kw AC Dummy Generator/Genset Resistive Load Bank for Generator Testing
Company Profile
Founded in 2024, Yuafeng Electrics focuses on high-performance load box manufacturing and global export, and has successfully served customers in 6 countries including Canada, Kazakhstan, UAE, Tanzania, Chile and Peru. The company has passed ISO 9001 quality management system and CE certification to ensure that each device meets international safety standards.
Core advantages
1) Accurate testing: Resistive/resistive load box accuracy reaches ±3%, covering 0-5000kW power range
2) Scenario customization: generator set testing, ship shore power verification, data center UPS aging
3) Global delivery: support EXW/FOB/DDU/CIF trade terms, provide multi-language operation manuals
4) Agile service: 24-hour technical response, lifelong maintenance support
FAQ
1, What is the HS code for the load bank?
The HS code is 9030899090
2, What is the delivery time?
Generally 25-45 days based on the quantity and power capacity of the load bank.
3, Do you accepted customized service?
Yes.
4, Do you accept factory inspection?
Yes. 
5, What's the power range of the load bank you can supply?
We can supply 2kW~5000kW,5kVA~5000kVA power capacity for each single load bank.
6, What's the resolution of its power adjustment?
It could be 1kW/1kvar resolution. We also supply infinite - step control for the power loading.
7, How to control the load bank temperature rising?
The temperature will be rising during the using process. Forced air cooling system will be used to control the temperature at a reasonable level in order to make sure the load bank work continuously and not be broken.
8, What control mode for the load bank can be supplied?
We supply 3 control mode for the load bank control include local panel button manual control mode,local panel touch screen control and remote PC control through Modbus TCP, PLC and control software that we supplied, remote control connection terminal include RJ45, RS232 and RS485,50-100m free super 6 category net cable will be supplied.
9, What are the main function for the remote PC control mode can supply?
Include turn on/turn off the load bank remotely;remote load and unload function;data save and printing;the load bank can working automatically after set the loading time, power and other parameters of the load bank in the control software like 0%-25%-50% -75% -100%-110% and how much time for each of these steps. You can check the voltage,power,current,power factor and frequency. And monitor the load bank running status such as running, standby, malfunction, etc., and send out remote alarms when abnormal situations (such as over voltage, over current, overheating, etc.) occur.
10, Are there detailed operation manuals and training materials?
Yes,easy to operate the load bank and with detailed operation manuals and training materials, we also supply operation video for each order.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier